Ergebnis 1 bis 5 von 5
Thema: Wrong button code ?
-
09.07.2017, 14:26 #1
- Registriert seit
- 01.02.2015
- Beiträge
- 184
- Thanks (gegeben)
- 134
- Thanks (bekommen)
- 131
- Total Downloaded
- 1,62 MB
- Total Downloaded
- 1,62 MB
Wrong button code ?
Hi there,
it looks like there's a bug in the Xtrend rc driver, or kernel.
the rc of the et9000/et9200 has a button called 'slow' or 'jump'. (it's the button in the picture with the red circle around it.)
the button code for this button is: 519
if i add a function to this button with Hotkey, ButtonSetup or MQB it works perfect.
but when i connect to the box with my pc (opewebif), and i press the 'slow' key on the virtual rc, nothing happens.
if i execute the buttoncode via telnet, nothing happens.
code: (look in text file)
all other button codes i execute in this way, work ok.
it looks like the buttoncode is wrong, or bad driver/kernel.
the problem is the same with other images, and other Xtrend models. (et8000/et10000)
can this be fixed, or has the support ended for these (driver/kernel) problems ?
grt LuciferGeändert von Lucifer (09.07.2017 um 14:31 Uhr)
-
Advertising
-
14.07.2017, 15:05 #2
- Registriert seit
- 31.01.2017
- Beiträge
- 694
- Thanks (gegeben)
- 25
- Thanks (bekommen)
- 297
- Total Downloaded
- 44,00 MB
- Total Downloaded
- 44,00 MB
Box 1:H7SBox 2:mipsel Boxcheck whether the keycode in
/usr/lib/enigma2/python/keyids.pyo
exists
you´ll probably need to decompile keyids.pyo first
-
Danke - 1 ThanksLucifer bedankten sich
-
15.07.2017, 11:33 #3
- Registriert seit
- 01.02.2015
- Beiträge
- 184
- Thanks (gegeben)
- 134
- Thanks (bekommen)
- 131
- Total Downloaded
- 1,62 MB
- Total Downloaded
- 1,62 MB
ThemenstarterHi there,
the problem is solved, i tested a lot of different button codes, and the right button code for the 'slow' button is: 408
i've been looking for button codes in the 'remote.html' file. path: /usr/share/enigma2/rc_models/et9x00/remote.html
this is a branding file from 'oe-alliance'. github link: branding-module/remote.html at master * oe-alliance/branding-module * GitHub
in this file there is a button called 'jump' with button code: 519
this button is not on the et9000 rc, and the button 'slow' is missing in the 'remote.html' file.
i think this file needs an update.
grt Lucifer
-
15.07.2017, 18:10 #4
- Registriert seit
- 31.01.2017
- Beiträge
- 694
- Thanks (gegeben)
- 25
- Thanks (bekommen)
- 297
- Total Downloaded
- 44,00 MB
- Total Downloaded
- 44,00 MB
Box 1:H7SBox 2:mipsel BoxI had a look into the keyids.py, there is no keycode 519, only
KEY_RESTART': 408
as you stated correctly, on my remote control I have a button WEB, not in use, I found out it is a
KEY_SEARCH': 217
now I use it for something else in keymap.xml
-
16.07.2017, 11:33 #5
- Registriert seit
- 01.02.2015
- Beiträge
- 184
- Thanks (gegeben)
- 134
- Thanks (bekommen)
- 131
- Total Downloaded
- 1,62 MB
- Total Downloaded
- 1,62 MB
Themenstarter@mrvica,
it's nice to hear that you have an extra option too.
i found the uncompiled version of keyids.pyo on github: enigma2/keyids.py at master * openatv/enigma2 * GitHub
there is script in the script section of this forum, that works with button codes.
the name of the script is fb.sh. here si the link: Fernbedienungstasten per Skript ausführen.
i have posted a few button code lists there myself, and a handy link.
grt Lucifer